SIEMENS CERT
01/12/2021
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …
SIEMENS CERT
01/12/2021
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
01/12/2021
Opcenter Execution Core (formerly known as Camstar Enterprise Platform) contains a cross-site scripting (CVE-2020-7576), an SQL injection (CVE-2020-7577), a privilege escalation (CVE-2020-7578), and an information disclosure vulnerability (CVE-2020-28930) in various versions of the product. Siemens has released an update for Opcenter Execution Core and recommends to update to the latest …
SIEMENS CERT
01/12/2021
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released updates for the affected products and recommends to update to the latest version(s).
SIEMENS CERT
12/08/2020
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative …
SIEMENS CERT
12/08/2020
An information disclosure vulnerability (CVE-2019-15126, also known as Kr00k) could allow an attacker to read a discrete set of traffic over the air after a Wi-Fi device state change. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
12/08/2020
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …
SIEMENS CERT
12/08/2020
A missing authentication vulnerability has been identified in SIEMENS LOGO!8 BM devices. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from the devices if the attacker has access to port 135/tcp.