SIEMENS CERT
12/09/2025
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
12/09/2025
SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
12/09/2025
SICAM T before V3.0 contain multiple vulnerabilities. These include critical issues such as improper parameter and input validation, various Cross-Site Scripting (XSS) vulnerabilities , and a Cross-Site Request Forgery (CSRF) vulnerability . Additional weaknesses comprise session fixation, authentication and authorization bypasses , missing HTTPS protection, and missing cookie protection flags. …
SIEMENS CERT
12/09/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
12/09/2025
Building X - Security Manager Edge Controller (ACC-AP) devices do not properly check the integrity of firmware updates. This could allow an attacker to upload a maliciously modified firmware onto the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet …
SIEMENS CERT
12/09/2025
Energy Services from Siemens (previously known as Managed Applications and Services), sell solutions using Elspec G5 devices that allows a person with physical access to the device to reset the Admin password by inserting a USB drive (containing a publicly documented reset string) into a USB port.
SIEMENS CERT
12/09/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …