CISA (ICS)
04/16/2026
Summary Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to systems and services. The following versions of Horner Automation Cscape and XL4, XL7 PLC are affected: Cscape v10.0 XL7 PLC v15.60 XL4 PLC v16.32.0 CVSS Vendor Equipment Vulnerabilities v3 9.1 Horner Automation Horner Automation Cscape …
SIEMENS CERT
04/14/2026
SIMOTION SCOUT, SIMOTION SCOUT TIA and SINAMICS STARTER are affected by an XXE injection vulnerability that could allow an attacker to access arbitrary application files. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes …
SIEMENS CERT
04/14/2026
SCALANCE W-700 IEEE 802.11n family before V6.6.0 are affected by multiple vulnerabilities. Siemens has released a new version for SCALANCE W-700 IEEE 802.11n family and recommends to update to the latest version.
SIEMENS CERT
04/14/2026
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to …
SIEMENS CERT
04/14/2026
RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains a vulnerability that could allow an attacker to achieve arbitrary code execution and to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version.
SIEMENS CERT
04/14/2026
Multiple Siemens products are affected by two local privilege escalation vulnerabilities which could allow an low privileged attacker to load malicious DLLs, potentially leading to arbitrary code execution with elevated privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/14/2026
Multiple vulnerabilities has been identified in Siemens SIMATIC IPCs, SIMATIC Tablet PCs, and SIMATIC Field PGs that can allow an authenticated attacker to alter the secure boot and password configurations. Siemens has released new versions of BIOS for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
04/14/2026
A vulnerability in affected devices could allow an attacker to perform a denial ofservice attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released new versions for several affected products and recommends to update to the latest …