Bulletins

SIEMENS CERT
05/13/2025
APOGEE PXC and TALON TC Series (BACnet) Devices devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the …
SIEMENS CERT
05/13/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
05/13/2025
MS/TP Point Pickup Module devices are affected by a denial of service vulnerability that could be triggered by an attacker residing in the same BACnet network by sending a specially crafted MSTP message. A power cycle is required to restore the device’s normal operation. Siemens recommends countermeasures for products where …
SIEMENS CERT
05/13/2025
Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
05/13/2025
An information disclosure vulnerability in SIPROTEC 5 devices could allow an unauthenticated, remote attacker to retrieve sensitive information of the device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products …
SIEMENS CERT
05/13/2025
The Mendix OIDC SSO module grants read and write access to all tokens exclusively to the Administrator role and could result in privilege misuse by an adversary modifying the module during Mendix development. Siemens has released a new version for Mendix OIDC SSO and recommends to update to the latest …
SIEMENS CERT
05/13/2025
Desigo CC deployments that use Installed Client are impacted by an information disclosure vulnerability which could result in information leak from the Desigo CC server. The other Desigo CC client options, Windows App Client and Flex Client, are not affected by this vulnerability. Siemens recommends specific countermeasures for products where …
US CERT
05/12/2025
Executive Summary This joint cybersecurity advisory (CSA) highlights a Russian state-sponsored cyber campaign targeting Western logistics entities and technology companies. This includes those involved in the coordination, transport, and delivery of foreign assistance to Ukraine. Since 2022, Western logistics entities and IT companies have faced an elevated risk of targeting …