SIEMENS CERT
08/12/2025
SSA-493787 V1.0: Arbitrary Code Execution Vulnerability in SIMATIC RTLS Locating Manager Before V3.2
SIMATIC RTLS Locating Manager Before V3.2 contains an improper input validation vulnerability that could allow an authenticated remote attacker to execute arbitrary code with high privileges. Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet …
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
08/12/2025
A vulnerability in TIA Project Server and TIA Portal could allow an attacker to cause a denial of service condition. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes …
US CERT
07/29/2025
Summary The Cybersecurity and Infrastructure Security Agency (CISA) and U.S. Coast Guard (USCG) are issuing this Cybersecurity Advisory to present findings from a recent CISA and USCG hunt engagement. The purpose of this advisory is to highlight identified cybersecurity issues, thereby informing security defenders in other organizations of potential similar …
CISA (ICS)
07/24/2025
1. EXECUTIVE SUMMARY CVSS v3 7.0 ATTENTION : Exploitable from a local network Vendor : Mitsubishi Electric Equipment : CNC Series Vulnerability : Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute malicious code by getting setup-launcher to load a malicious …
CISA (ICS)
07/24/2025
1. EXECUTIVE SUMMARY CVSS v3 9.4 ATTENTION : Exploitable remotely/low attack complexity Vendor : Honeywell Equipment : Experion PKS Vulnerabilities : Use of Uninitialized Variable, Improper Restriction of Operations within the Bounds of a Memory Buffer, Sensitive Information in Resource Not Removed Before Reuse, Integer Underflow (Wrap or Wraparound), Deployment …