Bulletins

SIEMENS CERT
05/10/2022
A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to disable and reset a device to factory state using a denial of service attack. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/10/2022
Desigo PXC3, PXC4, PXC5 and DXR2 devices contain multiple vulnerabilities in the webserver application that could allow an attacker to potentially intercept unencrypted transmission of sensitive information, cause a denial of service condition, or perform remote code execution. Siemens has released updates for the affected products and recommends to update …
SIEMENS CERT
05/10/2022
Siemens has released updates for JT2Go and Teamcenter Visualization to fix multiple file parsing vulnerabilities. If a user is tricked to open a malicious file (crafted as CGM, TIFF or TG4) with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code …
SIEMENS CERT
05/10/2022
The latest updates for SIMATIC RF products fix a vulnerability that could allow an unauthorized attacker to crash the OPC UA service of the affected devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/10/2022
Siemens Simcenter Femap versions before V2022.2 are affected by an out of bounds write vulnerability that could be triggered when the application reads files in .NEU format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote …
SIEMENS CERT
05/10/2022
Multiple vulnerabilities were identified in the webserver of SICAM P850 and SICAM P855 devices. These include unauthenticated access to web-interface functionality, missing HTTPS or impersonation as well as cross-site scripting related vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/10/2022
Vulnerability in the underlying third party component OPC UA ANSIC Stack (also called Legacy C-Stack) affects several industrial products. The vulnerability could cause a crash of the component that includes the vulnerable part of the stack. Siemens has released updates for several affected products and recommends to update to the …
SIEMENS CERT
05/10/2022
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …