Bulletins

SIEMENS CERT
04/13/2021
Siemens Tecnomatix RobotExpert version V16.1 fixes a vulnerability that could be triggered when the application reads CELL files. If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the …
SIEMENS CERT
04/13/2021
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerabilities described in this advisories are from this set. The DNS client of affected products contains two out of bounds write vulnerabilities in the handling of DNS responses that could allow an attacker …
SIEMENS CERT
04/13/2021
Several SCALANCE X-200 switches contain buffer overflow vulnerabilities in the web server. In the most severe case an attacker could potentially remotely execute code. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
04/13/2021
Security researchers discovered and disclosed 9 vulnerabilities in several DNS implementations, also known as “NAME:WRECK” vulnerabilities. The vulnerability described in this advisories is from this set. The DNS client of affected products contains a vulnerability related to the handling of UDP port numbers in DNS requests that could allow an …
SIEMENS CERT
04/13/2021
The IPv6 stack of affected products contains two vulnerabilities when processing IPv6 headers which could allow an attacker to cause a denial-of-service condition. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing updates and recommends specific countermeasures for products where …
SIEMENS CERT
03/09/2021
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative …
SIEMENS CERT
03/09/2021
The latest updates for SINEMA Remote Connect Client and Server fix multiple vulnerabilities. One of these vulnerabilities could allow an attacker to circumvent the authorization of the system for certain functionalities and to execute privileged functions. Siemens has released firmware updates for SINEMA Remote Connect Client and Server.