Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …
SIEMENS CERT
12/08/2020
A missing authentication vulnerability has been identified in SIEMENS LOGO!8 BM devices. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from the devices if the attacker has access to port 135/tcp.
SIEMENS CERT
12/08/2020
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative …
SIEMENS CERT
11/10/2020
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative …
SIEMENS CERT
11/10/2020
Siemens SCALANCE W1750D is a brandlabled device. Aruba has released a related security advisory (ARUBA-PSA-2016-004) [0] disclosing vulnerabilities in its Aruba Instant product line. The advisory contains multiple related vulnerabilities that are summarized in CVE-2016-2031. This advisory is a reminder to customers that the PAPI protocol is not a secure …
SIEMENS CERT
11/10/2020
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens is preparing updates and recommends specific countermeasures until fixes are available.
SIEMENS CERT
11/10/2020
A vulnerability has been identified in SIMATIC S7-300 and S7-400 CPU families and derived products, which could result in credential disclosure. Siemens recommends countermeasures as there are currently no fixes available.