Security researchers published information on vulnerabilities known as ZombieLoad and Microarchitectural Data Sampling (MDS). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
SIEMENS CERT
03/10/2020
A vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several affected products, and recommends …
SIEMENS CERT
03/10/2020
Two vulnerabilities have been identified in the SIMATIC S7-1200 and S7-1500 CPU families. One vulnerability could allow an attacker with network access to affected devices to modify the user program stored on these devices such that the source code differs from the actual running code. The other vulnerability could allow …
SIEMENS CERT
03/10/2020
SPPA-T3000 Application Server and MS3000 Migration Server are affected by multiple vulnerabilities. Some of the vulnerabilities can allow an attacker to execute arbitrary code on the server. Exploitation of the vulnerabilities described in this advisory requires access to either Application- or Automation Highway. Both highways should not be exposed if …
SIEMENS CERT
03/10/2020
SIMATIC S7-1500 CPU family devices are affected by a vulnerability that could allow an attacker to perform a Denial-of-Service attack if specially crafted UDP packets are sent to the device. Siemens has released updates for the affected products and recommends that customers update to these new versions.
SIEMENS CERT
03/10/2020
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
03/10/2020
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
03/10/2020
SiNVR V3 contains several vulnerabilities in the components Central Control Server (CCS), as well as in the FTP and streaming services of the Video Server. The vulnerabilities involve path traversal (CVE-2019-19290, CVE-2019-19296, CVE-2019-19297), information disclosure (CVE-2019-19291, CVE-2019-19299), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), insufficient logging (CVE-2019-19295), and denial-of-service (CVE-2019-19298). …