SIEMENS CERT
01/13/2026
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or …
SIEMENS CERT
01/13/2026
Versions V5.0 through V8 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could allow privilege …
SIEMENS CERT
01/13/2026
Siemens ET 200SP contains a denial-of-service vulnerability that could be triggered by sending a valid S7 protocol Disconnect Request (COTP DR TPDU), causing the device to become unresponsive and require a power cycle to recover. Siemens has released new versions for several affected products and recommends to update to the …
SIEMENS CERT
12/12/2025
Siemens Simcenter Femap versions before V2512 are affected by uninitialized memory vulnerability that could be triggered when the application reads files in SLDPRT format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in …
SIEMENS CERT
12/09/2025
SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
12/09/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
12/09/2025
SICAM T before V3.0 contain multiple vulnerabilities. These include critical issues such as improper parameter and input validation, various Cross-Site Scripting (XSS) vulnerabilities , and a Cross-Site Request Forgery (CSRF) vulnerability . Additional weaknesses comprise session fixation, authentication and authorization bypasses , missing HTTPS protection, and missing cookie protection flags. …