SIEMENS CERT
12/09/2025
SICAM T before V3.0 contain multiple vulnerabilities. These include critical issues such as improper parameter and input validation, various Cross-Site Scripting (XSS) vulnerabilities , and a Cross-Site Request Forgery (CSRF) vulnerability . Additional weaknesses comprise session fixation, authentication and authorization bypasses , missing HTTPS protection, and missing cookie protection flags. …
SIEMENS CERT
12/09/2025
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
12/09/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …
SIEMENS CERT
12/09/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
12/09/2025
Gridscale X Prepay contains multiple vulnerabilities that could allow an attacker to enumerate valid user names and to bypass locked-out user sessions. Siemens has released a new version for Gridscale X Prepay and recommends to update to the latest version.
SIEMENS CERT
12/09/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …
SIEMENS CERT
12/09/2025
Multiple Siemens products are affected by improper certificate validation in Siemens Advanced Licensing (SALT) Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for …
SIEMENS CERT
12/09/2025
Ruggedcom ROS devices contain a temporary denial of service vulnerability that could allow an attacker to crash and restart the device. Siemens has released new versions for the affected products and recommends to update to the latest versions.