Bulletins

SIEMENS CERT
05/13/2025
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and …
SIEMENS CERT
05/13/2025
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures …
SIEMENS CERT
05/13/2025
INTRALOG WMS before V5 is affected by multiple vulnerabilities in the Microsoft .NET implementation as described below. Siemens has released a new version for INTRALOG WMS and recommends to update to the latest version. Please approach your INTRALOG WMS contact to resolve the reported vulnerabilities for your solution. When contacting …
SIEMENS CERT
05/13/2025
Several SIMATIC S7-1500 and S7-1200 CPU versions are affected by an open redirect vulnerability that could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. For a successful attack, the legitimate user must actively click on an attacker-crafted link. Siemens …
SIEMENS CERT
05/13/2025
APOGEE PXC and TALON TC Series (BACnet) Devices devices start sending unsolicited BACnet broadcast messages after processing a specific BACnet createObject request. This could allow an attacker residing in the same BACnet network to send a specially crafted message that results in a partial denial of service condition of the …
SIEMENS CERT
05/13/2025
OZW672 and OZW772 Web Server versions contain vulnerabilities that could allow an attacker to execute arbitrary code on the device with root privileges (in versions before V8.0) or to authenticate as Administrator user (in versions before V6.0). Siemens has released new versions for the affected products and recommends to update …
SIEMENS CERT
05/13/2025
Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures …
SIEMENS CERT
05/13/2025
MS/TP Point Pickup Module devices are affected by a denial of service vulnerability that could be triggered by an attacker residing in the same BACnet network by sending a specially crafted MSTP message. A power cycle is required to restore the device’s normal operation. Siemens recommends countermeasures for products where …