Bulletins

SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
Products that include the Siemens PROFINET-IO (PNIO) stack in versMions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …
SIEMENS CERT
10/12/2021
The latest update for SINEC NMS fixes multiple vulnerabilities. The most severe could allow an authenticated remote attacker to execute arbitrary code on the system, with system privileges, under certain conditions. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
The latest update for RUGGEDCOM ROX devices fixes a vulnerability that could allow an unauthenticated attacker to cause a permanent Denial-of-Service condition under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability. Siemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for …
SIEMENS CERT
10/12/2021
The latest update for SIMATIC Process Historian (PH) fixes an authentication vulnerability in the configuration interface of redundant PH instances that could enable the execution of admin operations on the database. The related vulnerable interface is restricted to local access on recent versions starting from SIMATIC Process Historian 2020. Siemens …
SIEMENS CERT
10/12/2021
Multiple vulnerabilities in RUGGEDCOM ROX devices have been detected, ranging from command injection to filesystem traversal. An attacker could exploit these to gain root access to the affected devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates …