SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
08/12/2025
Siemens has released a new version for SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
A vulnerability was identified in RUGGEDCOM ROS devices with mirror port enabled, that could allow an attacker to inject information into the network via the mirror port. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products …
SIEMENS CERT
08/12/2025
The basic authentication mechanism of Mendix Runtime contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
08/12/2025
Affected SIPROTEC 5 devices do not properly limit the bandwidth for incoming network packets over their local USB port. This could allow an attacker with physical access to send specially crafted packets with high bandwidth to the affected devices thus forcing them to exhaust their memory and stop responding to …
SIEMENS CERT
08/12/2025
RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the …