SIEMENS CERT
08/12/2025
RUGGEDCOM ROX II devices do not properly limit access through their Built-In-Self-Test (BIST) mode. This could allow a local attacker to bypass authentication and access a root shell on the device. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
Mendix Runtime contains an observable response discrepancy vulnerability when validating usernames during authentication. This could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/12/2025
Siemens SINUMERIK Controllers are affected by an improper VNC password check vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/12/2025
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet …
SIEMENS CERT
08/12/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
Multiple vulnerabilities affect various third-party components of the RUGGEDCOM Operating System (ROS). If exploited, an attacker could cause a denial-of-service, act as a man-in-the-middle or retrieval of sensitive information or gain privileged functions. Siemens has released new versions for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
08/12/2025
The installers used to install several Siemens products are affected by a DLL hijacking vulnerability. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected installer component. This vulnerability poses a risk only during setup and installation phase of the …
SIEMENS CERT
08/12/2025
SIMOTION SCOUT, SIMOTION SCOUT TIA and SINAMICS STARTER are affected by an XXE injection vulnerability that could allow an attacker to access arbitrary application files. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends …