CISA (ICS)
03/10/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to bypass authentication and execute code with root-level privileges. The following versions of Lantronix EDS3000PS and EDS5000 are affected: EDS3000PS 3.1.0.0R2 (CVE-2025-67039, CVE-2025-70082, CVE-2025-67041) EDS5000 2.1.0.0R3 (CVE-2025-67034, CVE-2025-67035, CVE-2025-67036, CVE-2025-67037, CVE-2025-67038) CVSS Vendor Equipment Vulnerabilities v3 9.8 Lantronix Lantronix EDS3000PS …
CISA (ICS)
03/10/2026
Summary Successful exploitation of this vulnerability could allow an unauthorized attacker to access controller management settings, control components, disclose information, or cause a denial-of-service condition. The following versions of Honeywell IQ4 Series BMS Controller (Update A) are affected: IQ4E Firmware IQ412 Firmware IQ422 Firmware IQ4NC Firmware IQ41x Firmware CVSS Vendor …
CISA (ICS)
03/10/2026
Summary Successful exploitation of these vulnerabilities could allow an attacker to take control of the device or view camera feeds. The following versions of Apeman Cameras are affected: ID71 vers:all/* (CVE-2025-11126, CVE-2025-11851, CVE-2025-11852) CVSS Vendor Equipment Vulnerabilities v3 9.8 Apeman Apeman Cameras Insufficiently Protected Credentials, Improper Neutralization of Input During …
SIEMENS CERT
03/10/2026
Siemens SINAMICS G220, SINAMICS S210, and SINAMICS S200 contains a privilege escalation vulnerability that could allow users to escalate their privileges. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
03/10/2026
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. Customers are advised to consult and implement the workarounds …
SIEMENS CERT
03/10/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
03/10/2026
SIEMENS CERT
03/10/2026
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version for RUGGEDCOM APE1808 and recommends to update to the latest version.