SIEMENS CERT
10/11/2022
The FTP server of the networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable …
SIEMENS CERT
10/11/2022
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit multiple buffer overflow vulnerabilities that could lead to denial of service or unauthenticated remote code execution. Siemens has released updates for the SCALANCE W1750D and recommends to update to the latest version. Siemens …
SIEMENS CERT
10/11/2022
A vulnerability in the underlying third party component OPC UA ANSIC Stack (also called Legacy C-Stack) affects several industrial products. The vulnerability could cause a crash of the component that includes the vulnerable part of the stack. Siemens has released updates for several affected products and recommends to update to …
SIEMENS CERT
09/13/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
09/13/2022
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update …
SIEMENS CERT
09/13/2022
The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions still …
SIEMENS CERT
09/13/2022
Multiple vulnerabilities affecting various third-party components of SINEC INS before V1.0 SP2 could allow an attacker to cause a denial of service condition, disclose sensitive data or violate the system integrity. Siemens has released an update for the SINEC INS and recommends to update to the latest version.