Bulletins

SIEMENS CERT
06/08/2021
The latest update for TIM 1531 IRC fixes a vulnerability that could allow a remote attacker to cause a denial-of-service under certain circumstances. Siemens has released an update for the TIM 1531 IRC and recommends to update to the latest version.
SIEMENS CERT
06/08/2021
The latest update of Mendix SAML module fixes a privilege escalation vulnerability. Mendix has released an update for the Mendix SAML module and recommends to update to the latest version.
SIEMENS CERT
06/08/2021
Siemens has released version V13.1.0.3 for JT2Go and Teamcenter Visualization to fix a vulnerability that could be triggered when the products read files in TIFF file format. If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially …
SIEMENS CERT
06/08/2021
The latest updates for SIMATIC RF products fix a vulnerability that could allow an unauthorized attacker to crash the OPC UA service of the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
06/08/2021
Siemens has released a new version for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and …
SIEMENS CERT
06/08/2021
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens IPC related products, that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8745 …
SIEMENS CERT
06/08/2021
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates …
SIEMENS CERT
06/08/2021
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …