SIEMENS CERT
02/17/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to …
SIEMENS CERT
02/17/2022
Siemens Simcenter Femap versions before V2022.1.1 are affected by vulnerabilities that could be triggered when the application reads files in .NEU or .BDF format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to leak information or potentially perform …
SIEMENS CERT
02/17/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens has released updates for several affected products and recommends to update to the latest versions. …
SIEMENS CERT
02/08/2022
Vulnerabilities in the third-party component strongSwan could allow an attacker to cause a denial of service (DoS) condition in affected devices by exploiting integer overflow bugs. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
02/08/2022
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates …
SIEMENS CERT
02/08/2022
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has …
SIEMENS CERT
02/08/2022
All versions of the SIMATIC CP 443-1 OPC UA contain multiple vulnerabilities in the underlying third party component NTP. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
02/08/2022
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released an update …