SIMATIC NET CM 1542-1, SCALANCE SC600 family and SIMATIC NET CP 343-1 Advanced devices are vulnerable to a vulnerability in the third party component libcurl that could allow an attacker to cause a Denial-of-Service condition on the affected devices. Siemens has released an update for SCALANCE SC600. For the remaining …
SIEMENS CERT
05/11/2021
UltraVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/11/2021
Siemens Tecnomatix Plant Simulation has released an update for version V16.0 that fixes multiple vulnerabilities that could be triggered when the application reads SPP files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary …
SIEMENS CERT
05/11/2021
A denial-of-service vulnerability in WinCC Runtime could allow an unauthenticated attacker with network access to cause a denial-of-service condition in the SNMP service by sending crafted SNMP packets to port 161/udp. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/11/2021
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of two of these vulnerabilities (CVE-2020-13987, CVE-2020-17437) to Siemens products. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
04/14/2021
The latest updates for Mendix fix a vulnerability in Mendix Applications that could allow malicious authorized users to escalate their privileges. Mendix has released an update for Mendix and recommends to update to the latest version.
SIEMENS CERT
04/13/2021
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further updates and …
SIEMENS CERT
04/13/2021
Several firmware versions of the SCALANCE and RUGGEDCOM devices listed below are affected by a vulnerability in the passive listening feature that could allow an attacker to cause a reboot or, under specific circumstances, attain remote code execution of the affected devices. Siemens has released updates for the affected products …