SIEMENS CERT
10/11/2022
LOGO! 8 BM (incl. SIPLUS variants) contains a vulnerability that could allow an attacker to install manipulated firmware packages. Siemens has released an update for the LOGO! 8 BM (incl. SIPLUS variants) and recommends to update to the latest version.
SIEMENS CERT
10/11/2022
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens recommends specific countermeasures for products where updates are not, …
SIEMENS CERT
10/11/2022
JT Open Toolkit (JTTK) and Simcenter Femap are affected by an uninitialized pointer reference vulnerability that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application to crash or potentially lead …
SIEMENS CERT
10/11/2022
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not …
SIEMENS CERT
10/11/2022
Session fixation and incorrect parameter parsing vulnerabilities were identified in the web server of SICAM P850 and SICAM P855 devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/11/2022
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
09/13/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
09/13/2022
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update …