SIEMENS CERT
        03/10/2020
      
          The latest firmware update for the S7-300 CPUs fixes a vulnerability that could allow an unauthenticated attacker with network access to cause a denial-of-service condition. SINUMERIK 840D sl Controller, which contains a S7-300 CPU, is also affected. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
        
      
    SIEMENS CERT
        03/10/2020
      
          SiNVR V3 contains several vulnerabilities in the components Central Control Server (CCS), as well as in the FTP and streaming services of the Video Server. The vulnerabilities involve path traversal (CVE-2019-19290, CVE-2019-19296, CVE-2019-19297), information disclosure (CVE-2019-19291, CVE-2019-19299), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), insufficient logging (CVE-2019-19295), and denial-of-service (CVE-2019-19298). …
        
      
    SIEMENS CERT
        02/11/2020
      
          The firmware for SCALANCE S-600 family devices contains multiple web vulnerabilities. The vulnerabilities could allow an remote attacker to conduct Denial-of-Service attacks or perform Cross-Site Scripting attacks. Siemens recommends to migrate to SCALANCE SC-600 Industrial Security Appliances.
        
      
    SIEMENS CERT
        02/11/2020
      
          A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …
        
      
    SIEMENS CERT
        02/11/2020
      
          The latest update for SIMATIC CP 1543-1 contains two fixes for vulnerabilities within its embedded ProFTPD FTP server. The more severe of these vulnerabilities could allow for remote code execution and information disclosure without authentication. Siemens has released updates for SIMATIC CP 1543-1 modules.
        
      
    SIEMENS CERT
        02/11/2020
      
          A vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several affected products, and recommends …
        
      
    SIEMENS CERT
        02/11/2020
      
          A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …