05/14/2019
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect SISHIP Automation Solutions. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
SIEMENS CERT
05/14/2019
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
05/14/2019
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a Denial-of-Service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens provides updates …
SIEMENS CERT
05/14/2019
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …
SIEMENS CERT
05/14/2019
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project.
SIEMENS CERT
05/14/2019
Multiple vulnerabilities have been identified in SIEMENS LOGO!8 BM devices. The most severe vulnerability could lead to an attacker reading and modifying the device configuration if the attacker has access to port 10005/tcp.
SIEMENS CERT
05/14/2019
The latest update for SCALANCE W1750D fixes multiple vulnerabilities. The most severe could allow an unauthenticated attacker with access to the web interface of an affected device to execute arbitrary system commands within the underlying operating system. Siemens has released updates for the affected devices.
SIEMENS CERT
05/14/2019
SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II control contains a denial-of-service vulnerability within the Ethernet Modbus interface (G28). An attacker with access to the Ethernet Modbus Interface could cause a Denial-of-Service condition exceeding the number of available connections.