SIEMENS CERT
04/09/2019
SIMOCODE pro V EIP is affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released an update for SIMOCODE pro V EIP and recommends that customers update to the new version.
SIEMENS CERT
04/09/2019
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect WinCC OA. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
SIEMENS CERT
04/09/2019
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
04/09/2019
Versions of Spectrum Power™ 4, that use the customer specific project enhancement (PE) Web Office Portal (WOP) are affected by a possible OS Command Injection vulnerability. Siemens has released patches for the affected version and recommends to apply specific countermeasures until these patches can be applied.
SIEMENS CERT
04/09/2019
The latest updates for SINEMA Remote Connect Client and Server fix multiple vulnerabilities. One of these vulnerabilities could allow an attacker to circumvent the authorization of the system for certain functionalities and to execute privileged functions. Siemens has released firmware updates for SINEMA Remote Connect Client and Server.
SIEMENS CERT
03/12/2019
Security researchers published information on vulnerabilities known as Foreshadow and L1 Terminal Fault (L1TF). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
SIEMENS CERT
03/12/2019
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in various SCALANCE products does allow traffic to be directed back into the mirroring network. This …
SIEMENS CERT
03/12/2019
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.