Bulletins

SIEMENS CERT
09/14/2021
The latest update for Industrial Edge fixes a vulnerability that could allow an unauthenticated attacker to change the password of any user in the system. With this an attacker could impersonate any valid user on an affected system. Siemens has released updates for the affected products and recommends to update …
SIEMENS CERT
09/14/2021
Teamcenter Active Workspace contains a path traversal vulnerability that could lead to access control violations. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
09/14/2021
Devices of the LOGO! CMR family and the SIMATIC RTU 3000 family are affected by several vulnerabilities in the third party component Mbed TLS. They could allow an attacker with access to any of the interfaces of an affected device to impact the availability or to communicate with invalid certificates. …
SIEMENS CERT
09/14/2021
Several SCALANCE X switches contain vulnerabilities in the web server of the affected devices. An unauthenticated attacker could reboot, cause denial-of-service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for several affected products and recommends to update to the …
SIEMENS CERT
09/14/2021
The latest update for SINEMA Server fixes a vulnerability that could allow an unauthenticated attacker to obtain encoded system configuration backup files under certain conditions. Siemens has released an update for the SINEMA Server and recommends to update to the latest version.
SIEMENS CERT
09/14/2021
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released an update …
SIEMENS CERT
09/14/2021
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
SIEMENS CERT
09/14/2021
A buffer overflow vulnerability in the integrated web server of multiple APOGEE and TALON automation devices could allow a remote attacker to execute arbitrary code on the devices with root privileges. Affected devices include the APOGEE MBC/MEC/PXC P2 Ethernet devices with Power Open Processors (PPC), APOGEE PXC BACnet devices, and …