Bulletins

SIEMENS CERT
07/13/2021
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the …
SIEMENS CERT
07/13/2021
An incorrect authorization check in Mendix applications could allow an attacker to bypass write permissions to attributes of objects under certain circumstances. Mendix has released an update for Mendix and recommends to update to the latest version.
SIEMENS CERT
07/13/2021
Siemens has released version V13.0.2.0 for JT Utilities to fix multiple vulnerabilities that could be triggered when reading JT files. Siemens recommends to update to the latest version, which contains solutions to all the vulnerabilities listed in this advisory. Standing recommendation is to avoid opening of untrusted files from unknown …
SIEMENS CERT
07/13/2021
Siemens has released version SE2021MP5 for Solid Edge to fix multiple heap based buffer overflow vulnerabilities that could be triggered when the application read files in PAR or ASM file formats. If a user is tricked to open a malicious file with the affected application, this could lead to a …
SIEMENS CERT
06/08/2021
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …
SIEMENS CERT
06/08/2021
A vulnerability made public under the name SAD DNS affects Domain Name System resolvers due to a vulnerability in the Linux kernel when handling ICMP packets. The Siemens products which are affected are listed below. For more information please see https://www.saddns.net/. Siemens has released updates for several affected products and …
SIEMENS CERT
06/08/2021
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
06/08/2021
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …