08/11/2020
The latest updates for the affected products fix a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is …
SIEMENS CERT
08/11/2020
The latest update for SCALANCE M-800 / S615 and RUGGEDCOM RM1224 devices fixes a buffer overflow vulnerability in the third party component pppd that could allow an attacker with network access to an affected device to execute custom code on the device. Siemens has released updates for affected devices and …
SIEMENS CERT
08/11/2020
The extension module Advanced Reporting for Desigo CC and Desigo CC Compact contains a code injection vulnerability, which could be exploited if the extension module is installed on the server and configured. Siemens has released patches for the affected products and recommends specific countermeasures for unpatched systems.
SIEMENS CERT
08/11/2020
An information disclosure vulnerability (CVE-2019-15126, also known as Kr00k) could allow an attacker to read a discrete set of traffic over the air after a Wi-Fi device state change. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/11/2020
The latest update for Automation License Manager (ALM) fixes a vulnerability that could allow local users to locally escalate privileges and modify files that should be protected against writing. Siemens has released an update for ALM 6 and recommends that customers update to the latest version. Siemens recommends specific countermeasures …
SIEMENS CERT
08/11/2020
The latest update for SICAM A8000 RTUs fixes a vulnerability that could allow attackers with network access to the device’s web server to perform a stored Cross-Site-Scripting attack. Siemens has released an update for SICAM A8000 RTUs and recommends to update as soon as possible.
SIEMENS CERT
07/14/2020
There is an access mode used during manufacturing of SIMATIC S7-1200 and S7-200 SMART CPUs that allows additional diagnostic functionality. Using this functionality requires physical access to the CPU during boot process. If additional protection from unauthorized use is needed Siemens provides specific countermeasures via an update of the device …
SIEMENS CERT
07/14/2020
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …