Juli 2018
Titel
SSA-635129 (Last Update: 2018-07-11): Denial-of-Service Vulnerabilities in EN100 Ethernet Communication Module and SIPROTEC 5 relays
Veröffentlicht
11. Juli 2018 02:00
Text
The EN100 Ethernet communication module and SIPROTEC 5 relays are affected by security vulnerabilities which could allow an attacker to conduct a Denial-of-Service attack over the network. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes ...
Titel
Universal Robots Robot Controllers
Veröffentlicht
10. Juli 2018 16:10
Text
This advisory includes mitigation recommendations for use of hard-coded credentials and missing authentication for critical function vulnerabilities reported in the Universal Robots Robot Controllers.
Titel
Schweitzer Engineering Laboratories, Inc. Compass and AcSELerator Architect
Veröffentlicht
10. Juli 2018 16:00
Text
This advisory includes mitigations for incorrect default permissions, XXE, and resource exhaustion vulnerabilities in Schweitzer Engineering's Compass and AcSELerator software.
Titel
Rockwell Automation Allen-Bradley Stratix 5950
Veröffentlicht
3. Juli 2018 17:01
Text
This advisory includes mitigations for improper input validation, improper certificate validation, and resource management error vulnerabilities in the Allen-Bradley Stratix 5950 security appliance.
Titel
SSA-197012 (Last Update: 2018-07-03): Vulnerabilities in SICLOCK central plant clocks
Veröffentlicht
3. Juli 2018 02:00
Text
SICLOCK TC devices are affected by multiple vulnerabilities that could allow an attacker to cause Denial-of-Service conditions, bypass the authentication, and modify the firmware of the device or the administrative client. SICLOCK TC devices are in a phase out process. Siemens recommends mitigations to reduce the risk.
Juni 2018
Titel
Medtronic MyCareLink Patient Monitor
Veröffentlicht
28. Juni 2018 16:00
Text
This advisory includes mitigation recommendations for hard-coded password and exposed dangerous method or function vulnerabilities reported in Medtronic's MyCareLink Patient Monitors.
Titel
SSA-755010 (Last Update: 2018-06-26): Vulnerability in RAPIDLab 1200 and RAPIDPoint 400/500 Blood Gas Analyzers
Veröffentlicht
26. Juni 2018 02:00
Text
Siemens Healthineers has become aware of two potential cybersecurity vulnerabilities for the RAPIDLab® 1200 Series and RAPIDPoint® 400/405/500 Blood Gas Analyzers and recommends specific countermeasures to mitigate the risk. At the time of advisory publication, no public exploitation of this security vulnerability is known.
Titel
SSA-168644 (Last Update: 2018-06-26): Spectre and Meltdown Vulnerabilities in Industrial Products
Veröffentlicht
26. Juni 2018 02:00
Text
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
Titel
SSA-159860 (Last Update: 2018-06-26): Access Control Vulnerability in IEC 61850 system configurator, DIGSI 5, DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, and SICAM SCC
Veröffentlicht
26. Juni 2018 02:00
Text
IEC 61850 system configurator, DIGSI 5, DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, and SICAM SCC products are affected by a security vulnerability which could allow an attacker to either exfiltrate limited data from the system or to execute code with operating system user permissions. Siemens has released updates for ...
Titel
Delta Electronics Delta Industrial Automation COMMGR
Veröffentlicht
21. Juni 2018 16:00
Text
This advisory includes mitigations for a stack-based buffer overflow vulnerability in the Delta Electronics Delta Industrial Automation COMMGR software.
Titel
Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix (Update A)
Veröffentlicht
21. Juni 2018 15:55
Text
This updated advisory is a follow-up to the original advisory titled ICSA-18-172-02 Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix that was published June 21, 2018, on the NCCIC/ICS-CERT website. This updated advisory includes mitigation recommendations for an improper input validation vulnerability reported in Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix ...
Titel
Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix
Veröffentlicht
21. Juni 2018 15:55
Text
This advisory includes mitigation recommendations for an improper input validation vulnerability reported in Rockwell Automation Allen-Bradley CompactLogix and Compact GuardLogix controllers.
Titel
SSA-966341 (Last Update: 2018-06-19): SMBv1 Vulnerabilities in Molecular Diagnostics Products from Siemens Healthineers
Veröffentlicht
19. Juni 2018 02:00
Text
Select Molecular Diagnostics products from Siemens Healthineers are affected by the Microsoft Windows SMBv1 vulnerabilities. The exploitability of the vulnerabilities depends on the actual configuration and deployment environment of each product. Siemens Healthineers has developed solutions for all affected products which are available via customer support. Siemens Healthineers also provides ...
Titel
Natus Xltek NeuroWorks
Veröffentlicht
14. Juni 2018 18:05
Text
This medical device advisory includes mitigations for stack-based buffer overflow and out-of-bounds read vulnerabilities in the Natus Xltek NeuroWorks software.
Titel
Siemens SCALANCE X Switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C
Veröffentlicht
14. Juni 2018 16:10
Text
This advisory includes mitigation recommendations for a permissions, privileges, and access controls vulnerability reported in Siemens SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C.
Titel
Schneider Electric U.motion Builder
Veröffentlicht
12. Juni 2018 20:31
Text
This advisory includes mitigations for a command injection, cross-site scripting, and improper input validation vulnerabilities in the Schneider Electric U.motion Builder software.
Titel
Siemens SCALANCE X Switches
Veröffentlicht
12. Juni 2018 17:28
Text
This advisory includes mitigation recommendations for a cross-site scripting vulnerability reported in Siemens SCALANCE X switches.
Titel
SSA-701708 (Last Update: 2018-06-12): Local Privilege Escalation in Industrial Products
Veröffentlicht
12. Juni 2018 02:00
Text
In non-default configurations several industrial products are affected by a vulnerability that could allow local Microsoft Windows operating system users to escalate their privileges. Siemens provides updates for several products and a temporary fix for the remaining affected products. Siemens is working on new versions for the remaining affected products ...
Titel
SSA-323211 (Last Update: 2018-06-12): Vulnerabilities in SIPROTEC 4 and SIPROTEC Compact Devices
Veröffentlicht
12. Juni 2018 02:00
Text
SIPROTEC 4 and SIPROTEC Compact devices are affected by several vulnerabilities. Two of the vulnerabilities could allow attackers to perform a denial-of-service attack under certain conditions. Siemens has released updates for the affected products and will update this advisory when new information becomes available.
Titel
SSA-480829 (Last Update: 2018-06-12): Cross-Site-Scripting Vulnerabilities in SCALANCE X Switches
Veröffentlicht
12. Juni 2018 02:00
Text
Two cross-site-scripting (XSS) vulnerabilities were found in the web server of SCALANCE X switches. Siemens recommends updating the firmware to the newest version as soon as possible.
Titel
SSA-348629 (Last Update: 2018-06-12): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software
Veröffentlicht
12. Juni 2018 02:00
Text
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
Titel
SSA-977428 (Last Update: 2018-06-12): Vulnerabilities in SCALANCE M875
Veröffentlicht
12. Juni 2018 02:00
Text
Multiple vulnerabilities have been identified in the web interface of SCALANCE M875. The web interface of SCALANCE M875 could allow Cross-Site Request Forgery (CSRF), stored Cross-Site Scripting (XSS), or command injection attacks if an attacker is authenticated or tricks a legitimate authenticated user into accessing a malicious link. Siemens recommends ...
Titel
SSA-181018 (Last Update: 2018-06-12): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C
Veröffentlicht
12. Juni 2018 02:00
Text
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released ...
Titel
SSA-275839 (Last Update: 2018-06-12): Denial-of-Service Vulnerability in Industrial Products
Veröffentlicht
12. Juni 2018 02:00
Text
Several industrial products are affected by a vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. Siemens has released updates for several affected products, is working ...
Titel
SSA-523365 (Last Update: 2018-06-12): Vulnerability in SIMATIC PCS 7
Veröffentlicht
12. Juni 2018 02:00
Text
The latest software update for SIMATIC PCS 7 fixes a vulnerability, which could allow an attacker to cause a Denial-of-Service (DoS) condition under certain circumstances.