Bulletins

SIEMENS CERT
08/09/2022
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/09/2022
The products listed below contain two security vulnerabilities in the UMC component that could allow an attacker to cause a partial denial-of-service of the UMC component, or to locally escalate privileges from a user with administrative privileges to execute code with SYSTEM level privileges. Siemens has released updates for several …
SIEMENS CERT
08/09/2022
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products …
SIEMENS CERT
08/09/2022
Siemens Teamcenter Visualization and JT2Go are affected by an out of bounds write vulnerability in APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has …
SIEMENS CERT
08/09/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent . Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
08/09/2022
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens recommends specific countermeasures for products where updates …
SIEMENS CERT
08/09/2022
Teamcenter is affected by two security vulnerabilities in the File Service Cache service that could lead to command injection and denial of service issues. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/09/2022
Vulnerabilities in third-party component cURL could allow an attacker to interfere with the affected products in various ways. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.