Januar 2019
Titel
Emerson DeltaV
Veröffentlicht
10. Januar 2019 16:15
Text
This advisory provides mitigation recommendations for an authentication bypass vulnerability in Emerson's DeltaV distributed control system workstation products.
Titel
Omron CX-One CX-Protocol
Veröffentlicht
10. Januar 2019 16:10
Text
This advisory provides mitigation recommendations for a type confusion vulnerability in Omron's CX-Protocol within the CX-One software.
Titel
Pilz PNOZmulti Configurator
Veröffentlicht
10. Januar 2019 16:05
Text
This advisory provides mitigation recommendations for a clear-text storage of sensitive information vulnerability in the Pilz PNOZmulti Configurator, a safety circuit configuration tool.
Titel
Tridium Niagara Enterprise Security, Niagara AX, and Niagara 4
Veröffentlicht
10. Januar 2019 16:00
Text
This advisory was originally posted to the HSIN ICS-CERT library on November 29, 2018, and is now being released to the NCCIC/ICS-CERT website. This advisory provides mitigation recommendations for a cross-site scripting vulnerability reported in the Tridium Niagara Enterprise Security, the Niagara AX, and the Niagara 4 products.
Titel
Schneider Electric Zelio Soft 2
Veröffentlicht
8. Januar 2019 16:05
Text
This advisory provides mitigation recommendations for a use after free vulnerability in Schneider Electric's Zelio Soft 2 programming platform.
Titel
Schneider Electric IIoT Monitor
Veröffentlicht
8. Januar 2019 16:00
Text
This advisory includes mitigations for path traversal, unrestricted upload of file with dangerous type, and XXE vulnerabilities in the Schneider Electric IIoT Monitor software.
Titel
Schneider Electric IIoT Monitor (Update A)
Veröffentlicht
8. Januar 2019 16:00
Text
This updated advisory is a follow-up to the original advisory titled ICSA-19-008-02 Schneider Electric IIoT Monitor that was published January 08, 2019, on the NCCIC/ICS-CERT website. This updated advisory includes mitigations for path traversal, unrestricted upload of file with dangerous type, and XXE vulnerabilities in the Schneider Electric IIoT Monitor ...
Titel
SSA-293562 (Last Update: 2019-01-08): Vulnerabilities in Industrial Products
Veröffentlicht
8. Januar 2019 01:00
Text
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates ...
Titel
SSA-306710 (Last Update: 2019-01-08): Denial-of-Service Vulnerability in SIMATIC S7-300 CPU
Veröffentlicht
8. Januar 2019 01:00
Text
Siemens has released a firmware update for the SIMATIC S7-300 CPU family which fixes a vulnerability that could allow remote attackers to perform a Denial-of-Service attack.
Titel
SSA-348629 (Last Update: 2019-01-08): Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software
Veröffentlicht
8. Januar 2019 01:00
Text
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
Titel
SSB-439005 (Last Update: 2019-01-08): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
8. Januar 2019 01:00
Text
Titel
SSA-180635 (Last Update: 2019-01-08): Denial-of-Service Vulnerabilities in S7-1500 CPU
Veröffentlicht
8. Januar 2019 01:00
Text
Older versions of the S7-1500 CPU are affected by two Denial-of-Service vulnerabilities. Siemens has released updates for the currently supported hardware versions.
Titel
SSA-535640 (Last Update: 2019-01-08): Vulnerability in Industrial Products
Veröffentlicht
8. Januar 2019 01:00
Text
Various industrial products use the Discovery Service of the OPC UA protocol stack by the OPC foundation https://github.com/OPCFoundation/UA-.NETStandard and could therefore be affected by the remote resource consumption attacks (CVE-2017-12069).
Titel
SSA-181018 (Last Update: 2019-01-08): Heap Overflow Vulnerability in SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C
Veröffentlicht
8. Januar 2019 01:00
Text
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released ...
Titel
SSA-346262 (Last Update: 2019-01-08): Denial-of-Service in Industrial Products
Veröffentlicht
8. Januar 2019 01:00
Text
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates ...
Titel
SSA-579309 (Last Update: 2019-01-08): Denial-of-Service in SICAM A8000 Series
Veröffentlicht
8. Januar 2019 01:00
Text
The SICAM A8000 RTU series is affected by a security vulnerability that could allow unauthenticated remote users to cause a Denial-of-Service (DoS) condition of the web server of affected products. Siemens has released updates for all product variants and recommends that customers update to the new versions.
Titel
SSA-325546 (Last Update: 2019-01-08): Denial-of-Service Vulnerabilities in EN100 Ethernet Communication Module of SWT3000
Veröffentlicht
8. Januar 2019 01:00
Text
The firmware variant IEC 61850 of the EN100 Ethernet communication module for SWT 3000 is affected by security vulnerabilities which could allow an attacker to conduct a Denial-of-Service attack over the network. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and ...
Titel
SSA-592007 (Last Update: 2019-01-08): Denial-of-Service Vulnerability in Industrial Products
Veröffentlicht
8. Januar 2019 01:00
Text
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released ...
Titel
SSA-559174 (Last Update: 2019-01-08): Multiple Vulnerabilities in CP1604 and CP1616 devices
Veröffentlicht
8. Januar 2019 01:00
Text
Multiple vulnerabilities have been identified in SIEMENS CP1604 and CP1616 devices. The most severe of these vulnerabilities could allow an attacker to extract internal communication data or cause a Denial-of-Service condition.
Titel
Schneider Electric Pro-face GP-Pro EX
Veröffentlicht
3. Januar 2019 16:10
Text
This advisory provides mitigation recommendations for an improper input validation vulnerability in Schneider Electric's Pro-face GP-Pro EX, an HMI screen editor and logic programming software.
Titel
Yokogawa Vnet/IP Open Communication Driver
Veröffentlicht
3. Januar 2019 16:05
Text
This advisory provides mitigation recommendations for a resource management error vulnerability in Yokogawa's Vnet/IP open communication driver.
Titel
Hetronic Nova-M
Veröffentlicht
3. Januar 2019 16:00
Text
This advisory provides mitigation recommendations for an authentication bypass by capture-relay vulnerability in Hetronic's Nova-M remote control transmitters and receivers.
Dezember 2018
Titel
Horner Automation Cscape
Veröffentlicht
20. Dezember 2018 16:10
Text
This advisory provides mitigation recommendations for an improper input validation vulnerability in Horner Automation’s Cscape, a Control System Application programming software.
Titel
Schneider Electric EcoStruxure
Veröffentlicht
20. Dezember 2018 16:05
Text
This advisory provides mitigation recommendations for an open redirect vulnerability in Schneider Electric’s EcoStruxure, an IoT-enabled architecture and platform.
Titel
Rockwell Automation FactoryTalk Services Platform
Veröffentlicht
20. Dezember 2018 16:00
Text
This advisory was originally posted to the HSIN ICS-CERT library on November 27, 2018, and is being released to the NCCIC/ICS-CERT website. This advisory provides mitigation recommendations for a heap-based buffer overflow vulnerability in the Rockwell Automation FactoryTalk Services Platform.