Bulletins

SIEMENS CERT
11/08/2022
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. …
SIEMENS CERT
11/08/2022
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens is preparing updates and recommends specific countermeasures …
SIEMENS CERT
11/08/2022
The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions are …
SIEMENS CERT
11/08/2022
Multiple vulnerabilities (also known as “NUCLEUS:13”) have be identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf. CAPITAL VSTAR uses an affected version of the Nucleus software and inherently contains several of these vulnerabilities. Siemens recommends specific countermeasures for products where updates …
SIEMENS CERT
11/08/2022
QMS Automotive contains a vulnerability that stores user credentials in plantext within the user database. This could allow an attacker to read credentials from memory. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
11/08/2022
SICAM Q100 devices contain multiple vulnerabilities that could allow an attacker to take over the session of a logged in user or to inject custom code. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/08/2022
SINUMERIK ONE and SINUMERIK MC products are affected by a weak key protection vulnerability in the integrated S7-1500 CPU. The weak key protection vulnerability in the integrated S7-1500 CPU is documented in more detail in SSA-568427 [1]. Siemens is preparing updates and recommends specific countermeasures for products where updates are …
SIEMENS CERT
11/08/2022
The products listed below do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific …