SIEMENS CERT
05/11/2021
Multiple SmartVNC vulnerabilities in the affected products listed below could allow remote code execution and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest version.
SIEMENS CERT
05/11/2021
Security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. This advisory describes the impact of two of these vulnerabilities (CVE-2020-13987, CVE-2020-17437) to Siemens products. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
05/11/2021
Security researchers discovered and disclosed seven vulnerabilities in the open-source DNS component “dnsmasq”, also known as “DNSpooq” vulnerabilities (CVE-2020-25681 through CVE-2020-25687). Three vulnerabilities (CVE-2020-25684 through CVE-2020-25686) affect the validation of DNS responses and impact several SCALANCE and RUGGEDCOM devices as listed below. Siemens has released updates for several affected products …
SIEMENS CERT
05/11/2021
The installation of SIMARIS configuration causes insecure folder permissions that could allow vertical privilege escalation. Siemens has released an update for SIMARIS and recommends to update to the latest version.
SIEMENS CERT
05/11/2021
SSA-936080 V1.1 (Last Update: 2021-05-11): Multiple Vulnerabilities in Third-Party Component libcurl
SIMATIC NET CM 1542-1, SCALANCE SC600 family and SIMATIC NET CP 343-1 Advanced devices are vulnerable to a vulnerability in the third party component libcurl that could allow an attacker to cause a Denial-of-Service condition on the affected devices. Siemens has released an update for SCALANCE SC600. For the remaining …
SIEMENS CERT
05/11/2021
SCALANCE XM-400 and XR-500 devices contain a vulnerability in the OSPF protocol implementation that could allow an unauthenticated remote attacker to create a permanent denial-of-service condition. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/11/2021
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled on request by the system …
SIEMENS CERT
05/11/2021
A vulnerability made public under the name SAD DNS affects Domain Name System resolvers due to a vulnerability in the Linux kernel when handling ICMP packets. The Siemens products which are affected are listed below. For more information please see https://www.saddns.net/. Siemens has released updates for several affected products and …