SIEMENS CERT
04/12/2022
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens has released an update …
SIEMENS CERT
04/12/2022
Multiple industrial products are affected by a vulnerability in the kernel known as TCP SACK PANIC. The vulnerability could allow a remote attacker to cause a denial of service condition. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing further …
SIEMENS CERT
04/12/2022
Various industrial products use the Discovery Service of the OPC UA protocol stack by the OPC foundation https://github.com/OPCFoundation/UA-.NETStandard and could therefore be affected by the remote resource consumption attacks (CVE-2017-12069).
SIEMENS CERT
04/12/2022
Siemens Simcenter Femap versions before V2022.1.2 are affected by vulnerabilities that could be triggered when the application reads files in .NEU format. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to leak information or potentially perform remote code …
SIEMENS CERT
04/12/2022
When querying the database, it is possible to sort the results using a protected field. With this an authenticated attacker could extract information about the contents of a protected field. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/12/2022
Several SCALANCE X-300 switches contain multiple vulnerabilities. An unauthenticated attacker could reboot, cause denial of service conditions and potentially impact the system by other means through heap and buffer overflow vulnerabilities. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
04/12/2022
In conjunction with the installation of the affected products listed in the table below, a vulnerability in TIA Administrator occurs that could allow an unauthenticated attacker to perform a denial of service attack. Siemens has released a first update for one of the affected products and recommends to update to …
SIEMENS CERT
04/12/2022
SIMATIC Energy Manager is affected by multiple vulnerabilities that could allow an attacker to gain local privilege escalation, local code execution or remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.