Bulletins

SIEMENS CERT
01/28/2021
SIMATIC HMI Panels are affected by a vulnerability that could allow a remote attacker to gain full access to the device(s), if the telnet service is enabled. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
01/19/2021
Security researchers discovered and disclosed seven vulnerabilities in the open-source DNS component “dnsmasq”, also known as “DNSpooq” vulnerabilities (CVE-2020-25681 through CVE-2020-25687). Three vulnerabilities (CVE-2020-25684 through CVE-2020-25686) affect the validation of DNS responses and impact several SCALANCE and RUGGEDCOM devices as listed below. Siemens is preparing updates and recommends countermeasures for …
SIEMENS CERT
01/15/2021
Solid Edge is affected by multiple vulnerabilities that could allow arbitrary code execution on an affected system. Siemens has released an update for Solid Edge and recommends to update to the latest version.
SIEMENS CERT
01/12/2021
CISA and WIBU Systems disclosed six vulnerabilities in different versions of CodeMeter Runtime, a product provided by WIBU Systems and used in several Siemens and Siemens Energy products for license management. The vulnerabilities are described in the section “Vulnerability Classification” below and got assigned the CVE IDs CVE-2020-14509, CVE-2020-14513, CVE-2020-14515, …
SIEMENS CERT
01/12/2021
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …
SIEMENS CERT
01/12/2021
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …
SIEMENS CERT
01/12/2021
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Siemens has released updates for the affected products and recommends to update to the latest version(s).
SIEMENS CERT
01/12/2021
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software …