SIEMENS CERT
07/09/2019
Microsoft has released updates for several versions of Microsoft Windows, which fix a vulnerability in the Remote Desktop Service. The vulnerability could allow an unauthenticated remote attacker to execute arbitrary code on the target system if the system exposes the service to the network. Some Advanced Therapy products from Siemens …
SIEMENS CERT
07/09/2019
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
07/09/2019
The latest update for SIMATIC RF6XXR fixes multiple vulnerabilities related to outdated TLS versions that are still supported by the product. Siemens has released a fixed version for the SIMATIC RF6XXR and recommends updating.
SIEMENS CERT
07/09/2019
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends …
SIEMENS CERT
06/11/2019
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in various SCALANCE products does allow traffic to be directed back into the mirroring network. This …
SIEMENS CERT
06/11/2019
The latest update for the Siveillance VMS line fixes three security vulnerabilities that can cause remote privilege escalation. Siemens has released updates for the affected products and recommends to update affected devices as soon as possible.
SIEMENS CERT
06/11/2019
A vulnerability exists in the affected devices that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for some of the affected devices and is working on updates for …
SIEMENS CERT
06/11/2019
Two vulnerabilities have been identified in SIEMENS LOGO!8 devices. The Session ID on the integrated webserver of LOGO!8 devices is not invalidated upon logout. The second vulnerability could allow an attacker with network access to port 10005/tcp to cause a Denial-of-Service condition by sending specifically crafted packages to the service. …