Bulletins

SIEMENS CERT
03/10/2020
Two vulnerabilities have been identified in SIMATIC S7-300 and S7-400 CPU families. One vulnerability could lead to a Denial-of-Service, the other vulnerability could result in credential disclosure. Siemens recommends specific mitigations. Siemens will update this advisory when new information becomes available.
SIEMENS CERT
02/11/2020
OZW672 and OZW772 Web Server versions < 10.00 contain a vulnerability that could allow unauthenticated users to access project files under certain conditions. Siemens has released Version 10.00 that fixes the vulnerability and recommends to update all web servers.
SIEMENS CERT
02/11/2020
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
02/11/2020
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …
SIEMENS CERT
02/11/2020
The latest update for SIMATIC CP 1543-1 contains two fixes for vulnerabilities within its embedded ProFTPD FTP server. The more severe of these vulnerabilities could allow for remote code execution and information disclosure without authentication. Siemens has released updates for SIMATIC CP 1543-1 modules.
SIEMENS CERT
02/11/2020
A vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families. Siemens has released updates for several affected products, and recommends …
SIEMENS CERT
02/11/2020
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
02/11/2020
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific …