SIEMENS CERT
06/12/2018
Several industrial products are affected by a vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct Layer 2 access to the affected products. Siemens has released updates for several affected products, is working …
SIEMENS CERT
06/12/2018
Siemens Healthineers has become aware of two potential cybersecurity vulnerabilities for the RAPIDLab® 1200 Series and RAPIDPoint® 400/405/500 Blood Gas Analyzers and recommends specific countermeasures to mitigate the risk. At the time of advisory publication, no public exploitation of this security vulnerability is known.
SIEMENS CERT
06/12/2018
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …
SIEMENS CERT
06/12/2018
SIPROTEC 4 and SIPROTEC Compact devices are affected by several vulnerabilities. Two of the vulnerabilities could allow attackers to perform a denial-of-service attack under certain conditions. Siemens has released updates for the affected products and will update this advisory when new information becomes available.
SIEMENS CERT
05/29/2018
Security researchers published information on vulnerabilities known as Spectre and Meltdown. These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
SIEMENS CERT
05/23/2018
Siemens has released software updates for Siveillance VMS which fix a security vulnerability with the .NET Remoting deserialization that could allow elevation of privileges and/or causing a Denial-of-Service, if affected ports are exposed.
SIEMENS CERT
05/15/2018
SIPROTEC 4 and SIPROTEC Compact devices could allow access authorization passwords to be reconstructed or overwritten via engineering mechanisms that involve DIGSI 4 and EN100 Ethernet communication modules. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until …
SIEMENS CERT
05/15/2018
SIMATIC S7-400 CPUs are affected by a security vulnerability which could lead to a Denial-of-Service condition of the PLC if specially crafted packets are received and processed. The affected SIMATIC S7-400 CPU hardware versions are in the product cancellation phase or already phased-out. Siemens recommends customers either upgrading to a …