SIEMENS CERT
08/12/2025
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
Affected products contain a local arbitrary code execution vulnerability that could allow an attacker to perform actions against the operation system of that environment. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures …
SIEMENS CERT
08/12/2025
Siemens SINUMERIK Controllers are affected by an improper VNC password check vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …
SIEMENS CERT
08/12/2025
RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code or to create a denial of service condition. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the …
SIEMENS CERT
08/12/2025
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
08/12/2025
COMOS before V10.6 is affected by a local arbitrary code execution vulnerability in the integrated Open Design Alliance Drawings SDK. Siemens has released a new version for COMOS and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
The RUGGEDCOM RCDP protocol is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models and could allow unauthenticated remote users to perform administrative operations. An attacker must be in the same adjacent network and the RCDP daemon must be enabled in order to …