Bulletins

SIEMENS CERT
03/10/2020
The latest firmware update for the S7-300 CPUs fixes a vulnerability that could allow an unauthenticated attacker with network access to cause a denial-of-service condition. SINUMERIK 840D sl Controller, which contains a S7-300 CPU, is also affected. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
SIEMENS CERT
03/10/2020
SiNVR V3 contains several vulnerabilities in the components Central Control Server (CCS), as well as in the FTP and streaming services of the Video Server. The vulnerabilities involve path traversal (CVE-2019-19290, CVE-2019-19296, CVE-2019-19297), information disclosure (CVE-2019-19291, CVE-2019-19299), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), insufficient logging (CVE-2019-19295), and denial-of-service (CVE-2019-19298). …
SIEMENS CERT
03/10/2020
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is …
SIEMENS CERT
02/11/2020
The firmware for SCALANCE S-600 family devices contains multiple web vulnerabilities. The vulnerabilities could allow an remote attacker to conduct Denial-of-Service attacks or perform Cross-Site Scripting attacks. Siemens recommends to migrate to SCALANCE SC-600 Industrial Security Appliances.
SIEMENS CERT
02/11/2020
Security researchers published information on vulnerabilities known as ZombieLoad and Microarchitectural Data Sampling (MDS). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Siemens Industrial Products contain processors that are affected by the vulnerabilities.
SIEMENS CERT
02/11/2020
SIMATIC S7-1500 CPU family devices are affected by a vulnerability that could allow an attacker to perform a Denial-of-Service attack if specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, is working on updates for the remaining affected products and recommends specific …
SIEMENS CERT
02/11/2020
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is …
SIEMENS CERT
02/11/2020
A Denial-of-Service vulnerability was found in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC software when encrypted communication is enabled. The vulnerability could allow an attacker with network access to cause a Denial-of-Service condition under certain circumstances (versions prior to SIMATIC WinCC V7.3 or SIMATIC PCS 7 V8.1 are …