SIEMENS CERT
05/14/2024
Multiple SICAM products are affected by vulnerabilities that could lead to privilege escalation, remote code execution or information loss namely: SICAM A8000 device firmwares CPC80 for CP-8000/CP-8021/CP-8022 CPCI85 and OPUPI0 for CP-8031/CP-8050 SICAM EGS firmware CPCI85 and OPUPI0 SICAM 8 Software Solution SICORE Siemens has released new versions for the …
SIEMENS CERT
05/14/2024
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. Siemens has released a new version for Polarion ALM and recommends to update to the …
SIEMENS CERT
05/14/2024
The RUGGEDCOM CROSSBOW server application before V5.5 contains multiple vulnerabilities that could allow an attacker to execute arbitrary database queries via SQL injection attacks, or upload of arbitrary files to the application’s file system. The majority of the reported vulnerabilities might have a high impact in the availability of the …
SIEMENS CERT
05/14/2024
Tecnomatix Plant Simulation contains an out of bounds write vulnerability that could be triggered when the application reads MODEL files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target …
SIEMENS CERT
05/14/2024
The Apache Lucene based query engine in Polarion ALM lacks proper access controls. This could allow an authenticated user to query items beyond the user’s allowed projects. Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
SIEMENS CERT
05/14/2024
A denial of service vulnerability has been identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-313313: https://cert-portal.siemens.com/productcert/html/ssa-313313.html. The products listed below use affected versions of the Nucleus software and inherently contain the vulnerability. Siemens has released new versions for several affected products and …
SIEMENS CERT
05/14/2024
Siemens User Management Component (UMC) before V2.11.2 is affected by multiple vulnerabilities where the most severe could lead to a restart of the UMC server. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends …
SIEMENS CERT
05/14/2024
Several industrial products contain an out of bounds read vulnerability that could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel, leading to denial of service condition. Siemens has released new versions for several affected products and recommends to update to the …