SIEMENS CERT
05/11/2021
Security researchers discovered and disclosed seven vulnerabilities in the open-source DNS component “dnsmasq”, also known as “DNSpooq” vulnerabilities (CVE-2020-25681 through CVE-2020-25687). Three vulnerabilities (CVE-2020-25684 through CVE-2020-25686) affect the validation of DNS responses and impact several SCALANCE and RUGGEDCOM devices as listed below. Siemens has released updates for several affected products …
SIEMENS CERT
05/11/2021
The installation of SIMARIS configuration causes insecure folder permissions that could allow vertical privilege escalation. Siemens has released an update for SIMARIS and recommends to update to the latest version.
SIEMENS CERT
05/11/2021
SSA-936080 V1.1 (Last Update: 2021-05-11): Multiple Vulnerabilities in Third-Party Component libcurl
SIMATIC NET CM 1542-1, SCALANCE SC600 family and SIMATIC NET CP 343-1 Advanced devices are vulnerable to a vulnerability in the third party component libcurl that could allow an attacker to cause a Denial-of-Service condition on the affected devices. Siemens has released an update for SCALANCE SC600. For the remaining …
SIEMENS CERT
05/11/2021
UltraVNC vulnerabilities in the affected products listed below could allow remote code execution, information disclosure and Denial-of-Service attacks under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
05/11/2021
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens Controllers that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8744 “BIOS Advisory” …
SIEMENS CERT
05/11/2021
A vulnerability made public under the name SAD DNS affects Domain Name System resolvers due to a vulnerability in the Linux kernel when handling ICMP packets. The Siemens products which are affected are listed below. For more information please see https://www.saddns.net/. Siemens has released updates for several affected products and …
SIEMENS CERT
05/11/2021
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled on request by the system …
SIEMENS CERT
04/14/2021
The latest updates for Mendix fix a vulnerability in Mendix Applications that could allow malicious authorized users to escalate their privileges. Mendix has released an update for Mendix and recommends to update to the latest version.