Bulletins

SIEMENS CERT
01/14/2020
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in several SCALANCE X switches does allow traffic to be directed back into the mirroring network. …
SIEMENS CERT
01/14/2020
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
01/14/2020
A vulnerability in the affected devices could allow an unauthorized attacker with network access to the webserver of an affected device to perform a denial-of-service attack. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends …
SIEMENS CERT
01/14/2020
A vulnerability exists in several SCALANCE X switches that could allow external entities to reconstruct passwords for users of the affected devices if an attacker is able to obtain a backup of the device configuration. Siemens has released updates for some of the affected devices and is working on updates …
SIEMENS CERT
01/14/2020
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
12/10/2019
RUGGEDCOM Win is affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The vulnerabilities affect the underlying Wind River VxWorks network stack and were recently patched by Wind River. Siemens is working on updates for the …
SIEMENS CERT
12/10/2019
SPPA-T3000 Application Server and MS3000 Migration Server are affected by multiple vulnerabilities. Some of the vulnerabilities can allow an attacker to execute arbitrary code on the server. Exploitation of the vulnerabilities described in this advisory requires access to either Application- or Automation Highway. Both highways should not be exposed if …