November 2022
Titel
SSA-787941 V1.0: Denial of Service Vulnerability in RUGGEDCOM ROS V4
Veröffentlicht
8. November 2022 01:00
Text
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. ...
Titel
SSA-638652 V1.1 (Last Update: 2022-11-08): Authentication Bypass Vulnerability in Mendix SAML Module
Veröffentlicht
8. November 2022 01:00
Text
The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions are ...
Titel
SSA-459643 V1.1 (Last Update: 2022-11-08): Denial of Service Vulnerability in RUGGEDCOM ROS before V5.6.0
Veröffentlicht
8. November 2022 01:00
Text
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens ...
Titel
SSA-764417 V1.5 (Last Update: 2022-11-08): Weak Encryption Vulnerability in RUGGEDCOM ROS Devices
Veröffentlicht
8. November 2022 01:00
Text
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens is preparing updates and recommends specific countermeasures ...
Titel
SSA-362164 V1.2 (Last Update: 2022-11-08): Predictable Initial Sequence Numbers in the TCP/IP Stack of Nucleus RTOS
Veröffentlicht
8. November 2022 01:00
Text
The networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) use Initial Sequence Numbers for TCP-Sessions that are predictable. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not available.
Oktober 2022
Titel
SSA-640732 V1.0: Authentication Bypass Vulnerability in Siveillance Video Mobile Server
Veröffentlicht
21. Oktober 2022 02:00
Text
The mobile server component of Siveillance Video 2022 R2 contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to access the application without a valid account. Siemens has released a hotfix for Siveillance Video 2022 R2 and recommends to apply the hotfix on all installations of the ...
Titel
SSA-280624 V1.1 (Last Update: 2022-10-11): Multiple Vulnerabilities in SCALANCE W1750D
Veröffentlicht
11. Oktober 2022 02:00
Text
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit multiple buffer overflow vulnerabilities that could lead to denial of service or unauthenticated remote code execution. Siemens has released updates for the SCALANCE W1750D and recommends to update to the latest version. Siemens ...
Titel
SSA-258115 V1.0: DWG File Parsing Vulnerability in Solid Edge before SE2022MP9
Veröffentlicht
11. Oktober 2022 02:00
Text
Solid Edge is affected by a heap overflow vulnerability that could be triggered when the application reads DWG files. If a user is tricked to open a malicious file with the affected application, an attacker could leverage the vulnerability to perform remote code execution in the context of the current ...
Titel
SSA-254054 V1.3 (Last Update: 2022-10-11): Spring Framework Vulnerability (Spring4Shell or SpringShell, CVE-2022-22965) - Impact to Siemens Products
Veröffentlicht
11. Oktober 2022 02:00
Text
A vulnerability in Spring Framework was disclosed, that could allow remote unauthenticated attackers to execute code on vulnerable systems. The vulnerability is tracked as CVE-2022-22965 and is also known as “Spring4Shell” or “SpringShell”. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-285795 V1.3 (Last Update: 2022-10-11): Denial of Service in OPC-UA in Industrial Products
Veröffentlicht
11. Oktober 2022 02:00
Text
A vulnerability in the underlying third party component OPC UA ANSIC Stack (also called Legacy C-Stack) affects several industrial products. The vulnerability could cause a crash of the component that includes the vulnerable part of the stack. Siemens has released updates for several affected products and recommends to update to ...
Titel
SSA-250085 V1.1 (Last Update: 2022-10-11): Multiple Vulnerabilities in SINEC NMS
Veröffentlicht
11. Oktober 2022 02:00
Text
SINEC NMS contains multiple vulnerabilities that could allow an attacker to execute arbitrary code on the system, arbitrary commands on the local database or achieve privilege escalation. Siemens has released an update for SINEC NMS to fix CVE-2022-24281 and recommends to update to the latest version. Siemens is preparing further ...
Titel
SSA-306654 V1.4 (Last Update: 2022-10-11): Insyde BIOS Vulnerabilities in Siemens Industrial Products
Veröffentlicht
11. Oktober 2022 02:00
Text
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
Titel
SSA-501891 V1.0: Cross-Site Scripting Vulnerability in SCALANCE X-200 and X-200IRT Families
Veröffentlicht
11. Oktober 2022 02:00
Text
There is a cross-site scripting vulnerability that affects the SCALANCE switches. This vulnerability if used by a threat actor could result in the stealing of session cookies and session hijacking. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-446448 V1.4 (Last Update: 2022-10-11): Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack
Veröffentlicht
11. Oktober 2022 02:00
Text
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further ...
Titel
SSB-439005 V4.8 (Last Update: 2022-10-11): Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
Veröffentlicht
11. Oktober 2022 02:00
Text
Titel
SSA-552702 V1.0: Privilege Escalation Vulnerability in the Web Interface of SCALANCE and RUGGEDCOM Products
Veröffentlicht
11. Oktober 2022 02:00
Text
The products listed below do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific ...
Titel
SSA-649853 V1.0: Improper Certificate Validation Vulnerability in Industrial Edge Management
Veröffentlicht
11. Oktober 2022 02:00
Text
Industrial Edge Management contains a vulnerability that could allow an unauthenticated attacker to spoof a trusted entity by interfering in the communication path between the Industrial Edge Management (IEM) and the Industrial Edge Hub (IEH) using a crafted certificate. An attacker could use this to inject malicious maintenance requests (e.g. ...
Titel
SSA-611756 V1.0: JT File Parsing Vulnerability in JTTK and Simcenter Femap
Veröffentlicht
11. Oktober 2022 02:00
Text
JT Open Toolkit (JTTK) and Simcenter Femap are affected by an uninitialized pointer reference vulnerability that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application to crash or potentially lead ...
Titel
SSA-572005 V1.0: Vulnerabilities in the Web Server of SICAM P850 and SICAM P855 Devices
Veröffentlicht
11. Oktober 2022 02:00
Text
Session fixation and incorrect parameter parsing vulnerabilities were identified in the web server of SICAM P850 and SICAM P855 devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-384224 V1.0: Denial of Service Vulnerability in SIMATIC HMI Panels
Veröffentlicht
11. Oktober 2022 02:00
Text
Several SIMATIC HMI Panels are affected by a vulnerability that could allow an attacker to cause a permanent denial of service condition (requiring a device reboot) by sending specially crafted TCP packets. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-712929 V1.4 (Last Update: 2022-10-11): Denial of Service Vulnerability in OpenSSL (CVE-2022-0778) Affecting Industrial Products
Veröffentlicht
11. Oktober 2022 02:00
Text
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest ...
Titel
SSA-697140 V1.0: Denial of Service Vulnerability in the TCP Event Service of SCALANCE and RUGGEDCOM Products
Veröffentlicht
11. Oktober 2022 02:00
Text
The products listed below contain a denial of service vulnerability in the TCP event interface that could allow an unauthenticated remote attacker to render the device unusable. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends ...
Titel
SSA-360783 V1.0: Multiple Webserver Vulnerabilities in Desigo PXM Devices
Veröffentlicht
11. Oktober 2022 02:00
Text
Desigo PXM devices contain multiple vulnerabilities in the webserver application that could allow an attacker to potentially access sensitive information, execute arbitrary commands, cause a denial of service condition, or perform remote code execution. Siemens has released updates for the affected products and recommends to update to the latest versions.
Titel
SSA-685781 V1.1 (Last Update: 2022-10-11): Multiple Vulnerabilities in Apache HTTP Server Affecting Siemens Products
Veröffentlicht
11. Oktober 2022 02:00
Text
Multiple vulnerabilities were identified in the Apache HTTP Server software. These include NULL Pointer Dereferencing, Out-of-bounds Write and Server-Side Request Forgery related vulnerabilities. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not, or ...
Titel
SSA-244969 V1.8 (Last Update: 2022-10-11): OpenSSL Vulnerability in Industrial Products
Veröffentlicht
11. Oktober 2022 02:00
Text
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1l and 1.0.2 < 1.0.2za that allows an attacker to cause a denial of service (DoS) or to disclose private memory content. Siemens has released updates for several affected products and recommends to update to ...

Letzte Updates

BOSCH PSIRT
31.10.2024
SIEMENS CERT
22.11.2024
US CERT
08.11.2024
US CERT (ICS)
21.11.2024

Nach Quelle

Archiv

2024
2023
2022
2021
2020
2019
2018
2017

Feeds