Bulletins

SIEMENS CERT
11/08/2022
SINEC NMS versions before V1.0.3 are affected by a vulnerability in the logback component (CVE-2021-42550) that could allow attackers with write access to the logback configuration file to execute arbitrary code on the system. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
SIEMENS CERT
11/08/2022
The networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) use Initial Sequence Numbers for TCP-Sessions that are predictable. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not available.
SIEMENS CERT
11/08/2022
Siemens Teamcenter Visualization and JT2Go are affected by multiple file parsing vulnerabilities that could be triggered when the application reads malicious TIF, CGM or PDF files. If a user is tricked to open a malicious TIF, CGM or PDF file with the affected products, this could lead the application to …
SIEMENS CERT
11/08/2022
There is a cross-site scripting vulnerability that affects the SCALANCE switches. This vulnerability if used by a threat actor could result in the stealing of session cookies and session hijacking. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/08/2022
RUGGEDCOM ROS-based V4 devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. …
SIEMENS CERT
11/08/2022
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens is preparing updates and recommends specific countermeasures …
SIEMENS CERT
11/08/2022
The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions are …
SIEMENS CERT
11/08/2022
Multiple vulnerabilities (also known as “NUCLEUS:13”) have be identified in the Nucleus RTOS (real-time operating system) and reported in the Siemens Security Advisory SSA-044112: https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf. CAPITAL VSTAR uses an affected version of the Nucleus software and inherently contains several of these vulnerabilities. Siemens recommends specific countermeasures for products where updates …