Bulletins

SIEMENS CERT
11/10/2026
SIMATIC IoT2050 devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released new versions for several affected products …
SIEMENS CERT
11/10/2026
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
11/10/2026
ROS# before version 2.3.1 contains a code injection vulnerability that could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Siemens has released a new version for ROS# and recommends to update to the latest …
SIEMENS CERT
11/10/2026
The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or …
SIEMENS CERT
11/10/2026
.NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the …
SIEMENS CERT
11/10/2026
Graphics Designer of SIMATIC WinCC before V8.2 contains an implicit active content execution vulnerability upon opening files, which could allow an attacker to cause arbitrary code execution on the device. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.
SIEMENS CERT
11/10/2026
meta-iot2050 (https://github.com/siemens/meta-iot2050) from V01.03.01 contains a Command Injection vulnerability in the firmware update tool that could allow an attacker which is able to manipulate a configuration file to have arbitrary commands run as root. Siemens is preparing fixes and recommends mitigations for products where fixes are not or not yet …
SIEMENS CERT
11/10/2026
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …