SIEMENS CERT
11/10/2026
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
11/10/2026
Graphics Designer of SIMATIC WinCC before V8.2 contains an implicit active content execution vulnerability upon opening files, which could allow an attacker to cause arbitrary code execution on the device. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.
SIEMENS CERT
11/10/2026
SIMATIC IoT2050 devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released new versions for several affected products …
SIEMENS CERT
11/10/2026
meta-iot2050 (https://github.com/siemens/meta-iot2050) from V01.03.01 contains a Command Injection vulnerability in the firmware update tool that could allow an attacker which is able to manipulate a configuration file to have arbitrary commands run as root. Siemens is preparing fixes and recommends mitigations for products where fixes are not or not yet …
SIEMENS CERT
11/10/2026
Fortinet has published information on vulnerabilities in FortiOS. This advisory lists the related Siemens Industrial products. Siemens recommends to contact customer support for additional information, and follow Fortinet advisory for workarounds and mitigation measures.
SIEMENS CERT
11/10/2026
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available.
SIEMENS CERT
11/06/2026
Siemens is currently assessing the impact of Node2Shell (CVE-2026-111497) on Industrial Edge. Please check your Industrial Edge Management (IEM) setup: No Management Applications installed: No action is required. Although the affected Brotli library is included in the IEM software stack, the affected functionality is not used or exposed. The same …
SIEMENS CERT
11/06/2026
On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as “Node2Shell” (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. …