Bulletins

SIEMENS CERT
12/13/2022
Several SCALANCE X switches are affected by an Authentication Bypass vulnerability. The vulnerability allows an unauthenticated attacker to violate access-control rules. The vulnerability can be exploited by sending a GET request to a specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be …
SIEMENS CERT
12/13/2022
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
12/13/2022
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
12/13/2022
SICAM PAS/PQS before V8.06 is affected by three vulnerabilities which could lead to remote code execution, privilege escalation or the creation of a denial of service condition. Siemens has released several updates for SICAM PAS/PQS and recommends to update to the latest version.
SIEMENS CERT
12/13/2022
The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions are …
SIEMENS CERT
12/13/2022
Polarion ALM contains a misconfiguration in its default Apache HTTP Server configuration that could allow an attacker to perform host header injection attacks. Siemens is preparing updates and recommends specific countermeasures for existing installations by checking for misconfigurations in configuration files.
SIEMENS CERT
12/13/2022
The SSH server on RUGGEDCOM ROS devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. Siemens has released updates for several affected products …
SIEMENS CERT
12/13/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …