SIEMENS CERT
10/11/2022
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve parts of the memory. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not …
SIEMENS CERT
10/11/2022
Insyde has published information on vulnerabilities in Insyde BIOS in February 2022. This advisory lists the Siemens Industrial products affected by these vulnerabilities. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
09/13/2022
Several Siemens industrial products are affected by a vulnerability in OpenSSL, that could result in data being sent out unencrypted by the SSL/TLS record layer. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
09/13/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
09/13/2022
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update …
SIEMENS CERT
09/13/2022
The Mendix SAML module insufficiently protects from packet capture replay. This could allow unauthorized remote attackers to bypass authentication and get access to the application. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version. Note: For compatibility reasons, fix versions still …
SIEMENS CERT
09/13/2022
Multiple vulnerabilities affecting various third-party components of SINEC INS before V1.0 SP2 could allow an attacker to cause a denial of service condition, disclose sensitive data or violate the system integrity. Siemens has released an update for the SINEC INS and recommends to update to the latest version.
SIEMENS CERT
09/13/2022
The boot loader within RUGGEDCOM ROS contains two vulnerabilities in the loading process of the operating system kernel. The more severe of these vulnerabilities could allow an attacker with local access to the device to execute arbitrary code on an affected device. Siemens recommends specific countermeasures to mitigate this issue.