Bulletins

SIEMENS CERT
11/14/2023
Solid Edge is affected by a file parsing vulnerability in Drawings SDK from Open Design Alliance. If a user is tricked to open a malicious DWG file with the affected application, an attacker could leverage the vulnerability to crash the application or execute arbitrary code. Siemens has released updates for …
SIEMENS CERT
11/14/2023
A vulnerability was identified in RUGGEDCOM ROS devices with mirror port enabled, that could allow an attacker to inject information into the network via the mirror port. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends …
SIEMENS CERT
11/14/2023
Simcenter Femap is affected by out of bounds write vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context …
SIEMENS CERT
11/14/2023
Mendix Runtime contains a capture-replay flaw which could have an impact to apps built with the platform, if certain preconditions are met that depend on the app’s model and access control design. This could allow authenticated attackers to access or modify objects without proper authorization, or escalate privileges in the …
SIEMENS CERT
11/14/2023
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products …
SIEMENS CERT
11/14/2023
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
11/14/2023
Multiple vulnerabilities have been identified in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
11/14/2023
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …