SIEMENS CERT
07/12/2022
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the console. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are …
SIEMENS CERT
07/12/2022
EN100 Ethernet module is affected by memory corruption vulnerability (CVE-2022-30938). Siemens has released an update for the EN100 Ethernet module IEC 61850 variant and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
07/12/2022
Several models of SINAMICS PERFECT HARMONY GH180 Drives are affected by a DHCP client vulnerability (CVE-2021-29998) in the integrated SCALANCE X206-1 device. The vulnerability could allow an attacker to cause a heap-based buffer overflow on that device and use it to get access to the drive’s internal network. The list …
SIEMENS CERT
07/12/2022
Siemens has released updates for Opcenter Quality to fix an authentication bypass vulnerability. This could allow unauthenticated access to the application or cause denial of service condition for existing users. The issue is based on rich client modules using IbsGailWrapper-interface. After issuing the record the authentication bypass vulnerability could take …
SIEMENS CERT
07/12/2022
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
07/12/2022
The below referenced devices contain multiple vulnerabilities that could be exploited when the SINEMA Remote Connect Server (SRCS) VPN feature is used. The feature is not activated by default. The most severe could allow an attacker to execute arbitrary code with elevated privileges under certain circumstances. Siemens has released an …
SIEMENS CERT
07/12/2022
An expression injection vulnerability was discovered in the Workflow processing of Mendix Runtime, that can affect the running applications. The vulnerability could allow a malicious user to leak sensitive information if the Workflow visual language of Mendix is used. Mendix has released updates for the affected product lines, recommends to …
SIEMENS CERT
07/12/2022
A vulnerability was identified in the CPC80 firmware of SICAM A8000 devices. It could allow an unauthenticated remote attacker to cause a permanent denial of service condition. Siemens has released updates for the affected products and recommends to update to the latest versions.